ABB Contactor AF26Z-30-00-21 1SBL236001R2100

ABB Contactor AF26Z-30-00-21 1SBL236001R2100

  • Đăng ngày 26-03-2018 05:11:29 AM - 234 Lượt xem
  • Mã sản phẩm: AF26Z-30-00-21 1SBL236001R2100
  • ABB AF26Z-30-00-21 24-60V50/60HZ 20-60VDC Contactor 1SBL236001R2100
    • Number of Main Contacts NO:
    3
    • Number of Main Contacts NC:
    0
    • Number of Auxiliary Contacts NO:
    0
    • Number of Auxiliary Contacts NC:
    0
    • Standards:
    IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
    • Rated Operational Voltage:
    Main Circuit 690 V
    • Rated Frequency (f):
    Main Circuit 50 / 60 Hz
    • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A
    • Rated Operational Current AC-1 (Ie):
    (690 V) 40 °C 45 A
    (690 V) 60 °C 40 A
    (690 V) 70 °C 32 A
    • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 60 °C 26 A
    (380 / 400 V) 60 °C 26 A
    (415 V) 60 °C 26 A
    (440 V) 60 °C 26 A
    (500 V) 60 °C 23 A
    (690 V) 60 °C 17 A
    • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 6.5 kW
    (380 / 400 V) 11 kW
    (400 V) 11 kW
    (415 V) 11 kW
    (440 V) 15 kW
    (500 V) 15 kW
    (690 V) 15 kW
    • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
    • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
    • Maximum Electrical Switching Frequency:
    AC-1 600 cycles per hour
    AC-2 / AC-4 150 cycles per hour
    AC-3 1200 cycles per hour
    • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
    • Rated Impulse Withstand Voltage (Uimp):
    6 kV
    • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
    • Rated Control Circuit Voltage (Uc):
    50 Hz 24 ... 60 V
    60 Hz 24 ... 60 V
    DC Operation 20 ... 60 V
    • Operate Time:
    Between Coil De-energization and NC Contact Closing 13...98 ms
    Between Coil De-energization and NO Contact Opening 11...95 ms
    Between Coil Energization and NC Contact Opening 38...90 ms
    Between Coil Energization and NO Contact Closing 40...95 ms
    • Connecting Capacity Main Circuit:
    Flexible with Insulated Ferrule 1x 1.5...10 mm²
    Flexible with Insulated Ferrule 2x 1.5...4 mm²
    Flexible with Ferrule 1/2x 1.5...10 mm²
    Rigid 1/2x 2.5...10 mm²
    • Connecting Capacity Control Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
    Rigid 1/2x 1 ... 2.5 mm²
    • Wire Stripping Length:
    Control Circuit 10 mm
    Main Circuit 14 mm
    • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
    • Terminal Type:
    Screw Terminals
     
     

    0

    Tình trạng sản phẩm:


    ABB AF26Z-30-00-21 24-60V50/60HZ 20-60VDC Contactor 1SBL236001R2100
    • Number of Main Contacts NO:
    3
    • Number of Main Contacts NC:
    0
    • Number of Auxiliary Contacts NO:
    0
    • Number of Auxiliary Contacts NC:
    0
    • Standards:
    IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
    • Rated Operational Voltage:
    Main Circuit 690 V
    • Rated Frequency (f):
    Main Circuit 50 / 60 Hz
    • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A
    • Rated Operational Current AC-1 (Ie):
    (690 V) 40 °C 45 A
    (690 V) 60 °C 40 A
    (690 V) 70 °C 32 A
    • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 60 °C 26 A
    (380 / 400 V) 60 °C 26 A
    (415 V) 60 °C 26 A
    (440 V) 60 °C 26 A
    (500 V) 60 °C 23 A
    (690 V) 60 °C 17 A
    • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 6.5 kW
    (380 / 400 V) 11 kW
    (400 V) 11 kW
    (415 V) 11 kW
    (440 V) 15 kW
    (500 V) 15 kW
    (690 V) 15 kW
    • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
    • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
    • Maximum Electrical Switching Frequency:
    AC-1 600 cycles per hour
    AC-2 / AC-4 150 cycles per hour
    AC-3 1200 cycles per hour
    • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
    • Rated Impulse Withstand Voltage (Uimp):
    6 kV
    • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
    • Rated Control Circuit Voltage (Uc):
    50 Hz 24 ... 60 V
    60 Hz 24 ... 60 V
    DC Operation 20 ... 60 V
    • Operate Time:
    Between Coil De-energization and NC Contact Closing 13...98 ms
    Between Coil De-energization and NO Contact Opening 11...95 ms
    Between Coil Energization and NC Contact Opening 38...90 ms
    Between Coil Energization and NO Contact Closing 40...95 ms
    • Connecting Capacity Main Circuit:
    Flexible with Insulated Ferrule 1x 1.5...10 mm²
    Flexible with Insulated Ferrule 2x 1.5...4 mm²
    Flexible with Ferrule 1/2x 1.5...10 mm²
    Rigid 1/2x 2.5...10 mm²
    • Connecting Capacity Control Circuit:
    Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
    Rigid 1/2x 1 ... 2.5 mm²
    • Wire Stripping Length:
    Control Circuit 10 mm
    Main Circuit 14 mm
    • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
    • Terminal Type:
    Screw Terminals
     
     
         

     



    TÂN THÀNH CAM KẾT

    • Sản phẩm, hàng hóa chính hãng.
    • Giá cả cạnh tranh.
    • Dịch vụ chăm sóc khách hàng tận tâm.

    Thông Tin Công Ty

    Đã thông báo

     


    THÔNG TIN LIÊN HỆ
    CTY TNHH CÔNG NGHỆ SỐ TÂN THÀNH [Bản đồ]
    Trụ sở công ty: Số 189, Nguyễn Văn Linh, P. Kênh Dương, Q, Lê Chân, TP. Hải Phòng
    VPGD: Số 165-Thiên Lôi, P Vĩnh Niệm, Q Lê Chân. TP Hải Phòng
    VPĐD: Số 191- P Chùa Láng. Q Đống Đa. TP Hà Nội
    Tel: 0225.8830.305  Fax: 0225.8830.305
    Kinh doanh 1: 091.797.1515
    Kinh doanh 2: 083.797.1515
    Kinh doanh 3: 091.686.1515
    Website: http://tanthanhtech.com/
    Website: http://vienthongtanthanh.com/
    Website: http://tanthanh-automation.com/
    Email: tanthanhdigitech@gmail.com

  • Kết nối với chúng tôi