The hart475 Communicator is an upgraded version of the HART375 Communicator that works with meters that use the HART communication protocol to set, change, and display it to monitor input/output values and self-diagnosis results. Set the output and zero of constant current. When the system is started or maintained, the HART communicator can be used by connecting it to the 4~20mA communication signal line.
This communicator is suitable for communication operation of HART protocol intelligent transmitter. It is compatible with HART275, HART375 and HART475 handheld communicators . It has excellent compatibility and can be used to import imported instruments of 1151, 3051 , EJA, ABB and other HART protocols. It is compatible with all kinds of intelligent pressure (temperature) transmitters made in China. At the same time, it can communicate with the flowmeters that support HART protocol, such as electromagnetic flowmeter, V-cone flowmeter, target flowmeter, vortex flowmeter.
Features:
■ During the online monitoring and communication communication, the modulation signal will not interrupt the 4~20mA DC signal.
■ It can be shared with the instrument adopting the HART communication protocol. The HART communicator can be used together with all instruments adopting the HART communication protocol.
■ Convenient operation and large display screen (4 lines, 18 characters per line), displayed in Chinese, the user can see at a glance, easy to set and change
■ Information self-diagnosis / protection function
● Full-featured communication: communication support flow meter with HART protocol, temperature meter, change Transmitter
● Large screen display: Display interface is larger and clearer, adopts imported LCD screen
● Production test, diagnosis and inspection
for HART smart device ● Configuration, calibration, diagnosis, HART smart device in field operation maintenance, monitoring, etc.
● get HART field instruments manufacturer information
● understanding HART instrument working status and fault information
● read the meter output current and process variables
● get output parameters and values associated sensor
self-checking function
to format a password-protected
low Voltage alarm display
standard technical specifications
The technical specifications of the device are applicable to the instrument: ROSEMOUNT1151, ROSEMOUNT3051ABB Japan Fuji YOKOGAWA EJA (with HART communication protocol) and other imported pressure transmitters DS-1151, DS-3351HK1151, HK3151 and other domestic intelligent pressure transmitter
communication signal connection: special cable Length 1.1m (3.6ft) communication line: Length: 1Km (0.62 miles) (0.75~1.25mm2) Load resistance: 250~600Ω Load capacitance: 0.22uF or less Load inductance: 3.3mH or less and power line spacing: 15cm or more (Avoid parallel lines) Display: 128*64 dot matrix liquid crystal display control: touch switch (4 direction keys, 16 function keys, one power switch)
Function description/basic function:
●Set, change and display various parameters, HART communication
●Constant current output
●Zero additional function:
●Format protection needs to input password to format
●Battery alarm LCD display alarm message can prompt Battery voltage is low
● LCD contrast adjustment normal working conditions Ambient temperature: -15~55°C Storage conditions: Ambient temperature: 0~50°C