Rơle quá dòng, mất pha, Schneider Motor Protector EOCR-3E420

Rơle quá dòng, mất pha, Schneider Motor Protector EOCR-3E420

  • Đăng ngày 02-02-2019 02:13:59 AM - 597 Lượt xem
  • Mã sản phẩm: EOCR-3E420
  • ■ Based on MUC microcontroller (microprocessor control unit) 
    ■ Real-time process / high precision 
    ■ Enhanced monitoring function: monitoring distance up to 400 meters, 3-phase current display, pre-alarm (3DM2/FDM2) action reason description 
    ■ Monitoring function: provided Communication software for use on PC 
    ■ With overheating without current external transformer, current within 32A. Inverse time protection 
    ■ Suitable for three-phase / single-phase motor protection 
    ■ RoHS compliance 
    ■ Digital setting / action cause indication and fault Exclusion 
    ■Auto reset/reset time setting 
    ■ For FDM2/FMZ2, normal protection is guaranteed even if PDM is disco

    Tình trạng sản phẩm:


    EOCR-3DM2/EOCR-FDM2 Protection Project
    Protection project Setting range and conditions Action time
    Overcurrent When the current value on the load exceeds the set current value: 
    Setting range: 0.5 to 60 A (definite time limit) 
         0.5 to 32 A (inverse time limit)
    Time limit: between 0.2 and 30 seconds
    Inverse time limit & overheating inverse time limit: 1~30 Class
    Undercurrent The undercurrent set value cannot exceed or equal to the overcurrent set value when the current value on the load is lower than the set undercurrent 
    value.
    OFF, adjusted between 1 and 10 seconds
    Reverse phase This option can be used when the phase sequence reciprocal of the three-phase current is used 
    .
    Within 0.15 seconds
    Stall This value is set to several times the overcurrent set value. It is only suitable for the start-up process and its setting range can be adjusted. 
    0.5 to 30A: 2 to 8 times 
    to 40A of overcurrent setting value : 2 to 6 times 
    to 60A: 2 to 4 times
    After D-Time time (within 0.5 seconds)
    Stall This value is set to several times the overcurrent set value. It is only suitable for operation and its setting range can be adjusted. 
    0.5 to 50A: 1.5 to 5 times to 60A ofthe overcurrent setting value 
    : 1.5 to 4 times
    Adjust between 0.3 and 5 seconds
    Phase imbalance Condition: Current imbalance ≥ setting imbalance % 
    Setting range: 10 to 50% imbalance
    Adjust between 1 and 10 seconds
    Ground Condition: Ground current setting range when the ground current setting value is exceeded 
    : OFF, 0.05-10A
    Adjust between 0.5 and 5 seconds 
    -- 3MZ2/FMZ2 only --
    EOCR-3DM2/EOCR-FDM2 technical parameters

    Overcurrent
    Rated setting range (A) Definite time limit: 0.5~60A: More than 60A need to use external transformer  
      Inverse time limit: 0.5~60A: More than 32A need to use external transformer  
    Undercurrent Rated setting range (A) 0.5A ~ less than the OC setting  
    Action time characteristic Definite time/inverse time limit  
    time setting Definite time limit D-time 0~200 seconds    
    O-time 0.2~30 seconds    
    Inverse time limit (cLS) 1~30 classes  
    Ground D-time (Edt) 0~30s (3MZ2/FMZ2)  
    Ground O-time (Et) 0.05~10s (3MZ2/FMZ2)  
    Automatic reset 0.5s~20 minutes.  
    Reset mode Manual reset / electric reset / automatic reset  
    Control voltage Voltage 100~240VAC/DC (85% ~ 110%, Free voltage), 24VAC/DC (±5%).  
    frequency 50/60Hz  
    Power consumption Less than 7VA  
    Output capacity 3A/250VAC resistance.  
    structure 1a1b : OC or GR  
    1a : AL  
    display 7-segment LED 3-phase current value, ground current, trip cause, run time  
    Current amplitude display stick Operating current as a percentage of the set current is displayed  
    installation Panel Mounting (3DM2/3MZ2)  
    Flush mounting (FDM2/FMZ2)  
    insulation Between the outer casing and the line Over DC500V 10MΩ  
    Compressive strength Between the outer casing and the line 2kV, 50/60Hz, 1 minute.  
    Split grounding room 1kV, 50/60Hz, 1 minute.  
    Line room 2kV, 50/60Hz, 1 minute.  
    Electrostatic discharge (ESD) IEC61000-4-2 Discharge in air: ±8kv, terminal discharge: ±6kv  
    Electromagnetic radiation interference IEC61000-4-3 Third level: 10v/m, 80~1000MHZ  
    Electromagnetic discharge IEC61000-4-6 Third level: 10V, 0.15~80MHz  
    EFT/Burst lEC61000-4-4 Third level: ±2kv, 1 minute  
    surge IEC61000-4-5 Third level: 1.2 x 50μs, 4KV (0°, 90°, 180°, 270°)  
    Conducted interference CISPR11 Class A (conduction and radiation)  
    surroundings temperature Storage -40°C ~ +85°C    
    jobs -20°C ~ +60°C    
    humidity 30~85% RH without condensation  
    weight   3DM2 / 3MZ2 FDM2 / FMZ2
    Window type 265g 350g
    Through Bottom hole type 295g 390g
    Terminal type 295 + 120 = 415g 390 + 120 = 510g
    Display section (W/3M cable)   125g
    Power consumption Less than 7VA.    

     
         

     



    TÂN THÀNH CAM KẾT

    • Sản phẩm, hàng hóa chính hãng.
    • Giá cả cạnh tranh.
    • Dịch vụ chăm sóc khách hàng tận tâm.

    Thông Tin Công Ty

    Đã thông báo

     


    THÔNG TIN LIÊN HỆ
    CÔNG TY TNHH ĐIỆN-VIỄN THÔNG TÂN THÀNH
    Trụ sở: Số 243 (số 2/185) Đường Chùa Láng, tổ 11, Phường Láng Thượng, Quận Đống Đa, Thành phố Hà Nội
    VPĐD: 37/213 Thiên Lôi-Vĩnh Niệm-Lê Chân-HP
    Kinh doanh 1: 0917.971.515
    Kinh doanh 2: 0836.861.515
    Kinh doanh 3: 0816.861.515
    Kinh doanh 4: 0877.971.515 
    Kinh doanh 5: 0787.971.515
    Kinh doanh 6: 0944.427.299
    Website: http://tanthanhtech.com
    Website: http://diencongnghieptanthanh.com
    Website: http://tanthanh-automation.com
    Website: http://thietbitudongtanthanh.com
    Website: https://vienthongtanthanh.com
    Email: kinhdoanhtanthanhhn@gmail.com

  • Kết nối với chúng tôi